CONTALITRI MAGNETICI

CONTALITRI MAGNETICI

CONTALITRI MAGNETICI
MISURALITRI AL MINUTOPRESSIONE MASSIMA DI LAVOROMATERIALE CORPOCODICE
1/4" 0,3 - 6 L/M 50 BAR DELRIN .00377045
0,3 - 6 L/M 50 BAR POLYPROPYLENE M0377045
1 - 15 L/M 50 BAR DELRIN .00377050
1 - 15 L/M 50 BAR POLYPROPYLENE M0377050
1/2" 1 - 30 L/M 50 BAR DELRIN .00377051
1 - 30 L/M 50 BAR POLYPROPYLENE M0377051
3 - 60 L/M 50 BAR DELRIN .00377052
3 - 60 L/M 50 BAR POLYPROPYLENE M0377052
1" 10- 200  L/M 50 BAR DELRIN .00377053
10- 200  L/M 50 BAR POLYPROPYLENE M0377053
1 1/2" 20 - 400 L/M 40 BAR DELRIN .00377055
20 - 400 L/M 40 BAR POLYPROPYLENE M0377055
2" 45 - 900 LT/M 20 BAR DELRIN .00377060
45 - 900 LT/M 20 BAR POLYPROPYLENE M0377060
3" 100 - 2000 L/M 10 BAR DELRIN .00377070
100 - 2000 L/M 10 BAR POLYPROPYLENE M0377070
CONTALITRI PONY - MAGNETIC
MISURALITRI AL MINUTOPRESSIONE MASSIMA DI LAVOROMATERIALE CORPOCODICE
1/4" 0,3 - 6 L/M 50 BAR DELRIN PM377045
0,3 - 6 L/M 50 BAR POLYPROPYLENE PMM77045
1 - 15 L/M 50 BAR DELRIN P0377050
1 - 15 L/M 50 BAR POLYPROPYLENE PMM77050
1/2" 1 - 30 L/M 50 BAR DELRIN PM377051
1 - 30 L/M 50 BAR POLYPROPYLENE PMM77051
3 - 60 L/M 50 BAR DELRIN PM377052
3 - 60 L/M 50 BAR POLYPROPYLENE PMM77052
1" 10- 200  L/M 50 BAR DELRIN PM377053
10- 200  L/M 50 BAR POLYPROPYLENE PMM77053
1 1/2" 20 - 400 L/M 40 BAR DELRIN PM377055
20 - 400 L/M 40 BAR POLYPROPYLENE PMM77055
2" 45 - 900 LT/M 20 BAR DELRIN PM377060
45 - 900 LT/M 20 BAR POLYPROPYLENE PMM77060
3" 100 - 2000 L/M 10 BAR DELRIN PM377070
100 - 2000 L/M 10 BAR POLYPROPYLENE PMM77070
CONTALITRI PONY MAGNETIC SIGNAL
MISURALITRI AL MINUTOPRESSIONE MASSIMA DI LAVOROMATERIALE CORPOCODICE
1/4" 0,3 - 6 L/M 50 BAR DELRIN PMS77045
0,3 - 6 L/M 50 BAR POLYPROPYLENE PMSM7045
1 - 15 L/M 50 BAR DELRIN PMS77050
1 - 15 L/M 50 BAR POLYPROPYLENE PMSM7050
1/2" 1 - 30 L/M 50 BAR DELRIN PMS77051
1 - 30 L/M 50 BAR POLYPROPYLENE PMSM7051
3 - 60 L/M 50 BAR DELRIN PMS77052
3 - 60 L/M 50 BAR POLYPROPYLENE PMSM7052
1" 10- 200  L/M 50 BAR DELRIN PMS77053
10- 200  L/M 50 BAR POLYPROPYLENE PMSM7053
1 1/2" 20 - 400 L/M 40 BAR DELRIN PMS77055
20 - 400 L/M 40 BAR POLYPROPYLENE PMSM7055
2" 45 - 900 LT/M 20 BAR DELRIN PMS77060
45 - 900 LT/M 20 BAR POLYPROPYLENE PMSM7060
3" 100 - 2000 L/M 10 BAR DELRIN PMS77070
100 - 2000 L/M 10 BAR POLYPROPYLENE PMSM7070
View as List Grid

Items 1-15 of 50

Page
per page
Set Descending Direction
  1. DISPLAY REMOTO PER CONTALITRI MAGNETICO
    DISPLAY REMOTO PER CONTALITRI MAGNETICO
    Cod. 00379009.S

    Capace di misurare i litri al minuto ed i litri complessivamente erogati

    Si può impostare una quantità erogata, al raggiungimento della quale

    Possiamo avere un segnale in uscita a 12 volt.

    Questo segnale può esser trasformato in un cicalino sonoro o visivo per l'operatore oppure può chiudere una Elettrovalvola o una valvola motorizzata. 


    New
    No
  2. DISPLAY REMOTO PER CONTALITRI MAGNETICO
    DISPLAY REMOTO PER CONTALITRI MAGNETICO
    Cod. 00379009

    CAPACE DI MISURARE I LITRI AL MINUTO ED I LITRI COMPLESSIVAMENTE EROGATI


    New
    No
  3. MAGNETIC FLOW - INDUCTIVE FLOWMETER
    MAGNETIC FLOW - INDUCTIVE FLOWMETER
    Cod. PMSM7070
    MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
    MATERIAL
    MOPLEN
    SIZE
    3"
    FLOW RATE
    1 - 30 Lt/Min
    PRESSURE
    10 BAR
    New
    No
  4. MAGNETIC FLOW - INDUCTIVE FLOWMETER
    MAGNETIC FLOW - INDUCTIVE FLOWMETER
    Cod. PMS77070
    MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
    MATERIAL
    DELRIN
    SIZE
    3"
    FLOW RATE
    1 - 30 Lt/Min
    PRESSURE
    10 BAR
    New
    No
  5. MAGNETIC FLOW - INDUCTIVE FLOWMETER
    MAGNETIC FLOW - INDUCTIVE FLOWMETER
    Cod. PMSM7051
    MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
    MATERIAL
    MOPLEN
    SIZE
    1/2"
    FLOW RATE
    1 - 30 Lt/Min
    PRESSURE
    50 BAR
    New
    No
  6. MAGNETIC FLOW - INDUCTIVE FLOWMETER
    MAGNETIC FLOW - INDUCTIVE FLOWMETER
    Cod. PMSM7045
    MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
    MATERIAL
    MOPLEN
    SIZE
    1/4"
    FLOW RATE
    0.3 - 6 Lt/Min
    PRESSURE
    50 BAR
    New
    No
  7. MAGNETIC FLOW - INDUCTIVE FLOWMETER
    MAGNETIC FLOW - INDUCTIVE FLOWMETER
    Cod. PMS77045
    MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
    MATERIAL
    DELRIN
    SIZE
    1/4"
    FLOW RATE
    0.3 - 6 Lt/Min
    PRESSURE
    50 BAR
    New
    No
  8. MAGNETIC FLOW - INDUCTIVE FLOWMETER
    MAGNETIC FLOW - INDUCTIVE FLOWMETER
    Cod. PMM77070
    MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
    MATERIAL
    MOPLEN
    SIZE
    3"
    FLOW RATE
    100 - 2000 Lt/Min
    PRESSURE
    10 BAR
    New
    No
  9. MAGNETIC FLOW - INDUCTIVE FLOWMETER
    MAGNETIC FLOW - INDUCTIVE FLOWMETER
    Cod. PM377070
    MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
    MATERIAL
    DELRIN
    SIZE
    3"
    FLOW RATE
    100 - 2000 Lt/Min
    PRESSURE
    10 BAR
    New
    No
  10. MAGNETIC FLOW - INDUCTIVE FLOWMETER
    MAGNETIC FLOW - INDUCTIVE FLOWMETER
    Cod. PMM77051
    MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
    MATERIAL
    MOPLEN
    SIZE
    1/2"
    FLOW RATE
    1 - 30 Lt/Min
    PRESSURE
    50 BAR
    New
    No
  11. MAGNETIC FLOW - INDUCTIVE FLOWMETER
    MAGNETIC FLOW - INDUCTIVE FLOWMETER
    Cod. PM377051
    MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
    MATERIAL
    DELRIN
    SIZE
    1/2"
    FLOW RATE
    1 - 30 Lt/Min
    PRESSURE
    50 BAR
    New
    No
  12. MAGNETIC FLOW - INDUCTIVE FLOWMETER
    MAGNETIC FLOW - INDUCTIVE FLOWMETER
    Cod. P0377050
    MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
    MATERIAL
    DELRIN
    SIZE
    1/4"
    FLOW RATE
    1 - 15 Lt/Min
    PRESSURE
    50 BAR
    New
    No
  13. MAGNETIC FLOW - INDUCTIVE FLOWMETER
    MAGNETIC FLOW - INDUCTIVE FLOWMETER
    Cod. PMM77045
    MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
    MATERIAL
    MOPLEN
    SIZE
    1/4"
    FLOW RATE
    0.3 - 6 Lt/Min
    PRESSURE
    50 BAR
    New
    No
  14. MAGNETIC FLOW - INDUCTIVE FLOWMETER
    MAGNETIC FLOW - INDUCTIVE FLOWMETER
    Cod. PM377045
    MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
    MATERIAL
    DELRIN
    SIZE
    1/4"
    FLOW RATE
    0.3 - 6 Lt/Min
    PRESSURE
    50 BAR
    New
    No
  15. INDUCTIVE FLOWMETER
    INDUCTIVE FLOWMETER
    Cod. M0377045
    "MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Available in the versions with Delrin or polypropylene tunnel, 316 stainless steel bushings. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature."
    MATERIAL
    MOPLEN
    SIZE
    1/4"
    FLOW RATE
    0.3 - 6 Lt/Min
    PRESSURE
    50 BAR
    New
    No
View as List Grid

Items 1-15 of 50