FLOWMETERS
- RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RMF75253
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSR1VERSIONNoRAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM75253
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSR1VERSIONNoRAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RMF75255
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSZRVERSIONNoRAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM75255
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSZRVERSIONNoRAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RMF75252
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSceramicVERSIONNoRAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM75252
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSceramicVERSIONNoRAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RMF75251
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSNoVERSIONNoRAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM75251
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSNoVERSIONNoRAPID CHECK 20 BAR - NYLON BODY WITH THREADCod. 00375255
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (high or low volume, with stainless steel, ceramic, ruby and adjustable sapphire bearings) and a 4-20 mA sinusoidal-wave or square-wave sensor.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSZRRAPID CHECK 20 BAR - NYLON BODY WITH THREADCod. 00375253
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (high or low volume, with stainless steel, ceramic, ruby and adjustable sapphire bearings) and a 4-20 mA sinusoidal-wave or square-wave sensor.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSR1RAPID CHECK 20 BAR - NYLON BODY WITH THREADCod. 00375252
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (high or low volume, with stainless steel, ceramic, ruby and adjustable sapphire bearings) and a 4-20 mA sinusoidal-wave or square-wave sensor.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSceramicRAPID CHECK 20 BAR - NYLON BODY WITH THREADCod. 00375251
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (high or low volume, with stainless steel, ceramic, ruby and adjustable sapphire bearings) and a 4-20 mA sinusoidal-wave or square-wave sensor.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSNoRAPID CHECK 30/40 BAR - IXEF BODY WITH THREADED FLANGESCod. 00376251
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges in the following sizes: 2" BSP - NPT and flanged hose tail Ø 50. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE40 BARSUPPORTSNoRAPID CHECK 30/40 BAR - IXEF BODY WITH THREADED FLANGESCod. 00376255
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges in the following sizes: 2" BSP - NPT and flanged hose tail Ø 50. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE40 BARSUPPORTSZRRAPID CHECK 30/40 BAR - IXEF BODY WITH THREADED FLANGESCod. 00376253
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges in the following sizes: 2" BSP - NPT and flanged hose tail Ø 50. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE40 BARSUPPORTSruby