FLOWMETERS
- RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. BJ376012
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSZRRAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. BJ376008
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSceramicRAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. BJ376007
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSNoRAPID CHECK 20 BAR - NYLON BODY WITH THREADCod. 00376012
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (high or low volume, with stainless steel, ceramic, ruby and adjustable sapphire bearings) and a 4-20 mA sinusoidal-wave or square-wave sensor.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSZRRAPID CHECK 20 BAR - NYLON BODY WITH THREADCod. 00376106
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (high or low volume, with stainless steel, ceramic, ruby and adjustable sapphire bearings) and a 4-20 mA sinusoidal-wave or square-wave sensor.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSR1RAPID CHECK 20 BAR - NYLON BODY WITH THREADCod. 00376008
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (high or low volume, with stainless steel, ceramic, ruby and adjustable sapphire bearings) and a 4-20 mA sinusoidal-wave or square-wave sensor.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSceramicRAPID CHECK 20 BAR - NYLON BODY WITH THREADCod. 00376007
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (high or low volume, with stainless steel, ceramic, ruby and adjustable sapphire bearings) and a 4-20 mA sinusoidal-wave or square-wave sensor.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSNoRAPID CHECK 30/40 BAR - IXEF BODY WITH THREADED FLANGESCod. 00376016
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges in the following sizes: 2" BSP - NPT and flanged hose tail Ø 50. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE30 BARSUPPORTSZRRAPID CHECK 30/40 BAR - IXEF BODY WITH THREADED FLANGESCod. 00376102
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges in the following sizes: 2" BSP - NPT and flanged hose tail Ø 50. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE30 BARSUPPORTSrubyRAPID CHECK 30/40 BAR - IXEF BODY WITH THREADED FLANGESCod. 00376004
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges in the following sizes: 2" BSP - NPT and flanged hose tail Ø 50. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE30 BARSUPPORTSceramicRAPID CHECK 30/40 BAR - IXEF BODY WITH THREADED FLANGESCod. 00376003
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges in the following sizes: 2" BSP - NPT and flanged hose tail Ø 50. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE30 BARSUPPORTSNoMAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PMSM7060
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALPPSIZE2inchFLOW RATE45 - 900 Lt/MinPRESSURE20 BARMATERIALPPSIZE2inchFLOW RATE45 - 900 Lt/MinPRESSURE20 BARMAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PMM77060
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALPPSIZE2inchFLOW RATE45 - 900 Lt/MinPRESSURE20 BARMATERIALPPSIZE2inchFLOW RATE45 - 900 Lt/MinPRESSURE20 BARMAGNETIC FLOW - INDUCTIVE FLOWMETERCod. M0377060
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALPPSIZE2inchFLOW RATE45 - 900 Lt/MinPRESSURE20 BARMATERIALPPSIZE2inchFLOW RATE45 - 900 Lt/MinPRESSURE20 BARMAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PMS77060
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALDELRINSIZE2inchFLOW RATE45 - 900 Lt/MinPRESSURE20 BARMATERIALDELRINSIZE2inchFLOW RATE45 - 900 Lt/MinPRESSURE20 BAR