DISPLAYS
- NewPONY PLUS 5.4 - 12 VOLTDISPLAY FOR ELECTRONIC FLOWMETERCod. P0005810.4
"3,5” digital color touchscreen display. Photo sensor to regulate back lighting. French, English, Italian and German multilingual menu. USB port for data collection. Energy-saving with turning off after some minutes of inactivity. Choice of the number of decimals after comma. ISOBUS Protocol. Rear coupling system with provision of suction cup attachment. 12Vcc power supply. Connected to a flowmeter, the display indicates real time lit/min flowrate and total flowrate. Setting of desired quantities also available to obtain an outlet signal once the required value is reached. The outlet signal (2,6A) can produce luminous or audio pulses, can drive a 12Vcc gear motor or an electrovalve or an engine. Also compatible with RAM-MOUNT suction cup."
SUPPLY12VAPPLICATIONflowVERSIONTOUCH SCREENNewYesNewPONY PLUS 5.1 - 12 VOLT DISPLAY FOR ELECTRONIC FLOWMETERCod. P0005810-1
"3,5” digital color touchscreen display. Photo sensor to regulate back lighting. French, English, Italian and German multilingual menu. USB port for data collection. Energy-saving with turning off after some minutes of inactivity. Choice of the number of decimals after comma. ISOBUS Protocol. Rear coupling system with provision of suction cup attachment. It has two signals inputs for measuring the flow, speed and filling level. 12Vcc power supply. Connected to a flowmeter the display indicates cumulative volume delivered (resettable) up to 999.999 units and partial volume in different units of measure: litres, Usa gallons, mc/h. Setting of pulses for calibration of liquids under several temperatures and viscosities. Setting of pulses for flowmeters from ½” to 4”. Can be connected to square wave sensors. RAM-MOUNT suction cup compatible."
SUPPLY12VAPPLICATIONflowVERSIONTOUCH SCREENNewYesPONY PLUS 4Cod. 00379005
Liquid measuring and reading instrument with timed intermittent output signal. Liquid measuring and reading instrument with timed intermittent output signal. Connected to a flow meter it displays the real-time flow rate and the total flow rate. The desired quantity can be set to obtain an output signal (12 VDC 5A) controlled by a programmable timer. This function is activated at each multiple of the quantity set.
SUPPLY12VAPPLICATIONflowVERSIONNoPONY PLUS 4Cod. 00379015
Liquid measuring and reading instrument with timed intermittent output signal. Liquid measuring and reading instrument with timed intermittent output signal. Connected to a flow meter it displays the real-time flow rate and the total flow rate. The desired quantity can be set to obtain an output signal (12 VDC 5A) controlled by a programmable timer. This function is activated at each multiple of the quantity set.
SUPPLY12VAPPLICATIONflowVERSIONNoPONY PLUS 1PONY PLUS 1PONY PLUS 1PONY FLOW 5Cod. RC379016
DISPLAY FOR FLOW MEASUREMENT AND READING
The programmable multilingual graphic display can indicate: cumulative volume delivered (resettable), cumulative volume delivered (not resettable) and partial volume in different units of measure: litres/gallons per minute, cubic metres per hour. It can be applied to all our turbine flowmeters. Maximum reading error: ±1%. Backlit display. 9 Volts battery powered. Equipped with luminosity sensor to increase endurance and energy saving.
SUPPLY9VAPPLICATIONflowVERSIONRAPID CHECKPONY FLOW 5Cod. 0037901C
DISPLAY FOR FLOW MEASUREMENT AND READING
The programmable multilingual graphic display can indicate: cumulative volume delivered (resettable), cumulative volume delivered (not resettable) and partial volume in different units of measure: litres/gallons per minute, cubic metres per hour. It can be applied to all our turbine flowmeters. Maximum reading error: ±1%. Backlit display. 9 Volts battery powered. Equipped with luminosity sensor to increase endurance and energy saving.
SUPPLY9VAPPLICATIONflowVERSION<1inch STANDARDPONY FLOW 5Cod. 00379016
DISPLAY FOR FLOW MEASUREMENT AND READING
The programmable multilingual graphic display can indicate: cumulative volume delivered (resettable), cumulative volume delivered (not resettable) and partial volume in different units of measure: litres/gallons per minute, cubic metres per hour. It can be applied to all our turbine flowmeters. Maximum reading error: ±1%. Backlit display. 9 Volts battery powered. Equipped with luminosity sensor to increase endurance and energy saving.
SUPPLY9VAPPLICATIONflowVERSIONNo