Cod. P0005747 The tandem valve allows controlling suction and delivery of the sprayer with one structure completely substituting the two single valves. The drive levers are on the same axle so as to simplify the manoeuvres for liquid control in the various passages and functions. Aluminium body treated with a cataphoresis cycle. Viton O-rings and Teflon-PTFE seals. Interchangeable Nylon flanges with different couplings and sizes. Possibility of constructing various models based on the sizes and the number of ways you intend to use.
Cod. 68109699 The tandem valve allows controlling suction and delivery of the sprayer with one structure completely substituting the two single valves. The drive levers are on the same axle so as to simplify the manoeuvres for liquid control in the various passages and functions. Aluminium body treated with a cataphoresis cycle. Viton O-rings and Teflon-PTFE seals. Interchangeable Nylon flanges with different couplings and sizes. Possibility of constructing various models based on the sizes and the number of ways you intend to use.
Cod. 68109699.1 The tandem valve allows controlling suction and delivery of the sprayer with one structure completely substituting the two single valves. The drive levers are on the same axle so as to simplify the manoeuvres for liquid control in the various passages and functions. Aluminium body treated with a cataphoresis cycle. Viton O-rings and Teflon-PTFE seals. Interchangeable Nylon flanges with different couplings and sizes. Possibility of constructing various models based on the sizes and the number of ways you intend to use.
Cod. 68109599.1 The tandem valve allows controlling suction and delivery of the sprayer with one structure completely substituting the two single valves. The drive levers are on the same axle so as to simplify the manoeuvres for liquid control in the various passages and functions. Aluminium body treated with a cataphoresis cycle. Viton O-rings and Teflon-PTFE seals. Interchangeable Nylon flanges with different couplings and sizes. Possibility of constructing various models based on the sizes and the number of ways you intend to use.
Cod. 68109599 The tandem valve allows controlling suction and delivery of the sprayer with one structure completely substituting the two single valves. The drive levers are on the same axle so as to simplify the manoeuvres for liquid control in the various passages and functions. Aluminium body treated with a cataphoresis cycle. Viton O-rings and Teflon-PTFE seals. Interchangeable Nylon flanges with different couplings and sizes. Possibility of constructing various models based on the sizes and the number of ways you intend to use.
Cod. VTSC8500.AMP The tandem valve allows controlling suction and delivery of the sprayer with one structure completely substituting the two single valves. The drive levers are on the same axle so as to simplify the manoeuvres for liquid control in the various passages and functions. Aluminium body treated with a cataphoresis cycle. Viton O-rings and Teflon-PTFE seals. Interchangeable Nylon flanges with different couplings and sizes. Possibility of constructing various models based on the sizes and the number of ways you intend to use.
Cod. VTSC8600 The tandem valve allows controlling suction and delivery of the sprayer with one structure completely substituting the two single valves. The drive levers are on the same axle so as to simplify the manoeuvres for liquid control in the various passages and functions. Aluminium body treated with a cataphoresis cycle. Viton O-rings and Teflon-PTFE seals. Interchangeable Nylon flanges with different couplings and sizes. Possibility of constructing various models based on the sizes and the number of ways you intend to use.
Cod. VTSC8500 The tandem valve allows controlling suction and delivery of the sprayer with one structure completely substituting the two single valves. The drive levers are on the same axle so as to simplify the manoeuvres for liquid control in the various passages and functions. Aluminium body treated with a cataphoresis cycle. Viton O-rings and Teflon-PTFE seals. Interchangeable Nylon flanges with different couplings and sizes. Possibility of constructing various models based on the sizes and the number of ways you intend to use.
Cod. VTDC7000 The recirculation valve allows creating a closed rinsing cycle for the entire system. The water is drawn from the supplementary tank and once the rinsing cycle has been completed, the liquid is sent for distribution in the boom. The system allows rinsing the spraying parts several times consuming a reduced amount of clean water without wasting the water contained in the supplementary tank. In addition, the rinsing liquid is not drained into the main tank, but distributed in the field through the boom. You also have the dual advantage of not having to dilute the treatment mixture in the main tank and not having to further agitate the contents with the risk of producing foam. Aluminium body treated with a cataphoresis cycle. Viton O-rings and Teflon-PTFE seals. Interchangeable Nylon flanges with different couplings and sizes. Possibility of constructing various models based on the sizes.
Cod. 00379011 Available in the sizes 1”½ (20-400 l/min) and 2” (45-900 l/min). Maximum pressure 8 bar. Because there are no internal moving parts, it is particularly suitable for measuring aggressive liquids or with small suspended solid particles. Compared to the Pro-Flow version with turbine flowmeter, this model does not offer the acoustic signal, external 5A device control and level sensor connection functions.
Cod. 00379012 Available in the sizes 1”½ (20-400 l/min) and 2” (45-900 l/min). Maximum pressure 8 bar. Because there are no internal moving parts, it is particularly suitable for measuring aggressive liquids or with small suspended solid particles. Compared to the Pro-Flow version with turbine flowmeter, this model does not offer the acoustic signal, external 5A device control and level sensor connection functions.
Cod. 20130199 ELECTRICAL INTAKE SYSTEM. The peristaltic pumps are used to metre and transfer a liquid chemical product in units. The control system can operate on up a maximum of 4 peristaltic pumps for metering 4 liquid chemical products. The peristaltic pumps send the metered product to the piston pump which injects the chemical product into the pressure line. Two models: P100 and P150. Peristaltic pump P100 takes hoses of Ø3.2mm, Ø6.4mm and Ø9.6mm; peristaltic pump P150 takes hoses of Ø12mm and Ø17mm. These are activated by a a multiphase reduction motor with variable Rpm.
Cod. 20120599 ELECTRICAL INTAKE SYSTEM. The peristaltic pumps are used to metre and transfer a liquid chemical product in units. The control system can operate on up a maximum of 4 peristaltic pumps for metering 4 liquid chemical products. The peristaltic pumps send the metered product to the piston pump which injects the chemical product into the pressure line. Two models: P100 and P150. Peristaltic pump P100 takes hoses of Ø3.2mm, Ø6.4mm and Ø9.6mm; peristaltic pump P150 takes hoses of Ø12mm and Ø17mm. These are activated by a a multiphase reduction motor with variable Rpm.
Cod. 10435099 The kit can be installed on any model of ball valves and allows the user to excite, manually moving the lever, the microswitch card measuring the position of the ball, so that to forward it to a remote visual electronic system, properly connected to the connectors given as an equipment. It can be used in any application where it is not possible to motorise the ball valve but is necessary to know its position at distance. The microswitch card can be powered at 12 Vcc. and 24 Vcc., 5A maximum. The microswitch card is located inside an aluminium structure, carefully protected.
Cod. 10433799 The kit can be installed on any model of ball valves and allows the user to excite, manually moving the lever, the microswitch card measuring the position of the ball, so that to forward it to a remote visual electronic system, properly connected to the connectors given as an equipment. It can be used in any application where it is not possible to motorise the ball valve but is necessary to know its position at distance. The microswitch card can be powered at 12 Vcc. and 24 Vcc., 5A maximum. The microswitch card is located inside an aluminium structure, carefully protected.