Cod. 6341169V This product is used to clean chemical products out of emptied containers before they are disposed of. It consists of a central shaft on which rotates a fluid-activated nozzle that is able to rotate through 360° to spray the inner surfaces of the container. The nozzle has tips at its end which allows it to break the protective film on sealed containers holding chemical products. It is made using anticorrosive material. Versions: with 1/2” BSP male connector and 18x1.5 male connector. The version with valve is featured by a fixed nozzle starting to deliver only when the container, overturned, is pressed downwards, allowing the operator to work under safe conditions.
Cod. 63412499 This product is used to clean chemical products out of emptied containers before they are disposed of. It consists of a central shaft on which rotates a fluid-activated nozzle that is able to rotate through 360° to spray the inner surfaces of the container. The nozzle has tips at its end which allows it to break the protective film on sealed containers holding chemical products. It is made using anticorrosive material. Versions: with 1/2” BSP male connector and 18x1.5 male connector. The version with valve is featured by a fixed nozzle starting to deliver only when the container, overturned, is pressed downwards, allowing the operator to work under safe conditions.
Cod. 63411699 This product is used to clean chemical products out of emptied containers before they are disposed of. It consists of a central shaft on which rotates a fluid-activated nozzle that is able to rotate through 360° to spray the inner surfaces of the container. The nozzle has tips at its end which allows it to break the protective film on sealed containers holding chemical products. It is made using anticorrosive material. Versions: with 1/2” BSP male connector and 18x1.5 male connector. The version with valve is featured by a fixed nozzle starting to deliver only when the container, overturned, is pressed downwards, allowing the operator to work under safe conditions.
Cod. 00200530.1 IXEF body, Viton OR and PTFE-Teflon gaskets, AISI 316 stainless steel ball. Nylon interchangeable flanges with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate up to 600 lt/min. 8 seconds closing time, 0,2 Amp nominal absorption. The special setting of the section hole of the valve guarantees an exact and accurate control of flow. If applied along the lineat suction of a centrifugal pump, it allows a better steadiness of flow.
Cod. 00200500 "IXEF body, Viton OR and Teflon-PTFE gaskets, AISI 316 stainless steel ball with continuous flow system. Nylon interchangeable flanges
with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate up to 500 lt/min. 1,3 seconds
closing time, 0,3 nominal absorption. Also available with lateral or lower inlet."
Cod. 00200501 "IXEF body, Viton OR and Teflon-PTFE gaskets, AISI 316 stainless steel ball with continuous flow system. Nylon interchangeable flanges
with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate up to 500 lt/min. 1,3 seconds
closing time, 0,3 nominal absorption. Also available with lateral or lower inlet."
Cod. 00200701.ME "Plastic body, Viton OR and Teflon-PTFE gaskets, plastic ball. Nylon interchangeable flanges with various connections and sizes available.
Maximum operating pressure 20bar – 290PSI with flowrate beyond 1000 lt/min on the 2” ½ model. 3 seconds closing time, 0,6 Amp
nominal absorption. Available in the ON/OFF and PROPORTIONAL versions with the opportunity of applying the angular sensor to detect
the position of the ball."
Cod. 00200701 "Plastic body, Viton OR and Teflon-PTFE gaskets, plastic ball. Nylon interchangeable flanges with various connections and sizes available.
Maximum operating pressure 20bar – 290PSI with flowrate beyond 1000 lt/min on the 2” ½ model. 3 seconds closing time, 0,6 Amp
nominal absorption. Available in the ON/OFF and PROPORTIONAL versions with the opportunity of applying the angular sensor to detect
the position of the ball."
Cod. 44314799 EXTRACTABLE FLOWMETER easy to apply and connect to any pipe of different diameter for perfect flow measurement. The compact size allows only partially occupying the duct leaving the inner span of the pipe almost completely free. Sin-wave, square-wave and 4-20 mA sensors. Battery-operated or 12V electrically-operated displays to view units per minute and totals, expressed in litres, hectolitres, cubic metres or gallons. Error percentage: ±3%. Response time: 3 sec.
Cod. 44312899 EXTRACTABLE FLOWMETER easy to apply and connect to any pipe of different diameter for perfect flow measurement. The compact size allows only partially occupying the duct leaving the inner span of the pipe almost completely free. Sin-wave, square-wave and 4-20 mA sensors. Battery-operated or 12V electrically-operated displays to view units per minute and totals, expressed in litres, hectolitres, cubic metres or gallons. Error percentage: ±3%. Response time: 3 sec.
Cod. 44302799 EXTRACTABLE FLOWMETER easy to apply and connect to any pipe of different diameter for perfect flow measurement. The compact size allows only partially occupying the duct leaving the inner span of the pipe almost completely free. Sin-wave, square-wave and 4-20 mA sensors. Battery-operated or 12V electrically-operated displays to view units per minute and totals, expressed in litres, hectolitres, cubic metres or gallons. Error percentage: ±3%. Response time: 3 sec.
Cod. 44312799 EXTRACTABLE FLOWMETER easy to apply and connect to any pipe of different diameter for perfect flow measurement. The compact size allows only partially occupying the duct leaving the inner span of the pipe almost completely free. Sin-wave, square-wave and 4-20 mA sensors. Battery-operated or 12V electrically-operated displays to view units per minute and totals, expressed in litres, hectolitres, cubic metres or gallons. Error percentage: ±3%. Response time: 3 sec.
Cod. P0005810.4 "3,5” digital color touchscreen display. Photo sensor to regulate back lighting. French, English, Italian and German multilingual menu. USB
port for data collection. Energy-saving with turning off after some minutes of inactivity. Choice of the number of decimals after comma.
ISOBUS Protocol. Rear coupling system with provision of suction cup attachment. 12Vcc power supply. Connected to a flowmeter, the
display indicates real time lit/min flowrate and total flowrate. Setting of desired quantities also available to obtain an outlet signal once
the required value is reached. The outlet signal (2,6A) can produce luminous or audio pulses, can drive a 12Vcc gear motor or an electrovalve
or an engine. Also compatible with RAM-MOUNT suction cup."
Cod. 00379005 Liquid measuring and reading instrument with timed intermittent output signal. Liquid measuring and reading instrument with timed intermittent output signal. Connected to a flow meter it displays the real-time flow rate and the total flow rate. The desired quantity can be set to obtain an output signal (12 VDC 5A) controlled by a programmable timer. This function is activated at each multiple of the quantity set.