Cod. 00200501 "IXEF body, Viton OR and Teflon-PTFE gaskets, AISI 316 stainless steel ball with continuous flow system. Nylon interchangeable flanges
with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate up to 500 lt/min. 1,3 seconds
closing time, 0,3 nominal absorption. Also available with lateral or lower inlet."
Cod. 00200701.ME "Plastic body, Viton OR and Teflon-PTFE gaskets, plastic ball. Nylon interchangeable flanges with various connections and sizes available.
Maximum operating pressure 20bar – 290PSI with flowrate beyond 1000 lt/min on the 2” ½ model. 3 seconds closing time, 0,6 Amp
nominal absorption. Available in the ON/OFF and PROPORTIONAL versions with the opportunity of applying the angular sensor to detect
the position of the ball."
Cod. 00200701 "Plastic body, Viton OR and Teflon-PTFE gaskets, plastic ball. Nylon interchangeable flanges with various connections and sizes available.
Maximum operating pressure 20bar – 290PSI with flowrate beyond 1000 lt/min on the 2” ½ model. 3 seconds closing time, 0,6 Amp
nominal absorption. Available in the ON/OFF and PROPORTIONAL versions with the opportunity of applying the angular sensor to detect
the position of the ball."
Cod. 44314799 EXTRACTABLE FLOWMETER easy to apply and connect to any pipe of different diameter for perfect flow measurement. The compact size allows only partially occupying the duct leaving the inner span of the pipe almost completely free. Sin-wave, square-wave and 4-20 mA sensors. Battery-operated or 12V electrically-operated displays to view units per minute and totals, expressed in litres, hectolitres, cubic metres or gallons. Error percentage: ±3%. Response time: 3 sec.
Cod. 44312899 EXTRACTABLE FLOWMETER easy to apply and connect to any pipe of different diameter for perfect flow measurement. The compact size allows only partially occupying the duct leaving the inner span of the pipe almost completely free. Sin-wave, square-wave and 4-20 mA sensors. Battery-operated or 12V electrically-operated displays to view units per minute and totals, expressed in litres, hectolitres, cubic metres or gallons. Error percentage: ±3%. Response time: 3 sec.
Cod. 44302799 EXTRACTABLE FLOWMETER easy to apply and connect to any pipe of different diameter for perfect flow measurement. The compact size allows only partially occupying the duct leaving the inner span of the pipe almost completely free. Sin-wave, square-wave and 4-20 mA sensors. Battery-operated or 12V electrically-operated displays to view units per minute and totals, expressed in litres, hectolitres, cubic metres or gallons. Error percentage: ±3%. Response time: 3 sec.
Cod. 44312799 EXTRACTABLE FLOWMETER easy to apply and connect to any pipe of different diameter for perfect flow measurement. The compact size allows only partially occupying the duct leaving the inner span of the pipe almost completely free. Sin-wave, square-wave and 4-20 mA sensors. Battery-operated or 12V electrically-operated displays to view units per minute and totals, expressed in litres, hectolitres, cubic metres or gallons. Error percentage: ±3%. Response time: 3 sec.
Cod. P0005810.4 "3,5” digital color touchscreen display. Photo sensor to regulate back lighting. French, English, Italian and German multilingual menu. USB
port for data collection. Energy-saving with turning off after some minutes of inactivity. Choice of the number of decimals after comma.
ISOBUS Protocol. Rear coupling system with provision of suction cup attachment. 12Vcc power supply. Connected to a flowmeter, the
display indicates real time lit/min flowrate and total flowrate. Setting of desired quantities also available to obtain an outlet signal once
the required value is reached. The outlet signal (2,6A) can produce luminous or audio pulses, can drive a 12Vcc gear motor or an electrovalve
or an engine. Also compatible with RAM-MOUNT suction cup."
Cod. 00379005 Liquid measuring and reading instrument with timed intermittent output signal. Liquid measuring and reading instrument with timed intermittent output signal. Connected to a flow meter it displays the real-time flow rate and the total flow rate. The desired quantity can be set to obtain an output signal (12 VDC 5A) controlled by a programmable timer. This function is activated at each multiple of the quantity set.
Cod. 00379015 Liquid measuring and reading instrument with timed intermittent output signal. Liquid measuring and reading instrument with timed intermittent output signal. Connected to a flow meter it displays the real-time flow rate and the total flow rate. The desired quantity can be set to obtain an output signal (12 VDC 5A) controlled by a programmable timer. This function is activated at each multiple of the quantity set.
Cod. M0377045 "MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal
moving parts. Available in the versions with Delrin or polypropylene tunnel, 316 stainless
steel bushings. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter
consists of a centraI insulated part enclosed in a metal screen made of different types of
material, copper and stainless steel, to which the rigorously insulated electronic operating
components are connected. At the ends different attachments may be fitted to allow rapid
and compact coupling to other components of the sprayer control units. This inductive
magnetic flowmeter has a completely open tunnel without moving parts, indispensable for
measurement of certain liquids. The mixtures used in agricolture may have different characteristics
owing to the viscosity of the chemical and the temperature."
Cod. 00377045 "MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal
moving parts. Available in the versions with Delrin or polypropylene tunnel, 316 stainless
steel bushings. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter
consists of a centraI insulated part enclosed in a metal screen made of different types of
material, copper and stainless steel, to which the rigorously insulated electronic operating
components are connected. At the ends different attachments may be fitted to allow rapid
and compact coupling to other components of the sprayer control units. This inductive
magnetic flowmeter has a completely open tunnel without moving parts, indispensable for
measurement of certain liquids. The mixtures used in agricolture may have different characteristics
owing to the viscosity of the chemical and the temperature."
Cod. M0377070 "MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal
moving parts. Available in the versions with Delrin or polypropylene tunnel, 316 stainless
steel bushings. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter
consists of a centraI insulated part enclosed in a metal screen made of different types of
material, copper and stainless steel, to which the rigorously insulated electronic operating
components are connected. At the ends different attachments may be fitted to allow rapid
and compact coupling to other components of the sprayer control units. This inductive
magnetic flowmeter has a completely open tunnel without moving parts, indispensable for
measurement of certain liquids. The mixtures used in agricolture may have different characteristics
owing to the viscosity of the chemical and the temperature."
Cod. 00377070 "MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal
moving parts. Available in the versions with Delrin or polypropylene tunnel, 316 stainless
steel bushings. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter
consists of a centraI insulated part enclosed in a metal screen made of different types of
material, copper and stainless steel, to which the rigorously insulated electronic operating
components are connected. At the ends different attachments may be fitted to allow rapid
and compact coupling to other components of the sprayer control units. This inductive
magnetic flowmeter has a completely open tunnel without moving parts, indispensable for
measurement of certain liquids. The mixtures used in agricolture may have different characteristics
owing to the viscosity of the chemical and the temperature."