Cod. 00200530.1 IXEF body, Viton OR and PTFE-Teflon gaskets, AISI 316 stainless steel ball. Nylon interchangeable flanges with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate up to 600 lt/min. 8 seconds closing time, 0,2 Amp nominal absorption. The special setting of the section hole of the valve guarantees an exact and accurate control of flow. If applied along the lineat suction of a centrifugal pump, it allows a better steadiness of flow.
Cod. 00200500 "IXEF body, Viton OR and Teflon-PTFE gaskets, AISI 316 stainless steel ball with continuous flow system. Nylon interchangeable flanges
with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate up to 500 lt/min. 1,3 seconds
closing time, 0,3 nominal absorption. Also available with lateral or lower inlet."
Cod. 00200501 "IXEF body, Viton OR and Teflon-PTFE gaskets, AISI 316 stainless steel ball with continuous flow system. Nylon interchangeable flanges
with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate up to 500 lt/min. 1,3 seconds
closing time, 0,3 nominal absorption. Also available with lateral or lower inlet."
Cod. 00200701.ME "Plastic body, Viton OR and Teflon-PTFE gaskets, plastic ball. Nylon interchangeable flanges with various connections and sizes available.
Maximum operating pressure 20bar – 290PSI with flowrate beyond 1000 lt/min on the 2” ½ model. 3 seconds closing time, 0,6 Amp
nominal absorption. Available in the ON/OFF and PROPORTIONAL versions with the opportunity of applying the angular sensor to detect
the position of the ball."
Cod. 00200701 "Plastic body, Viton OR and Teflon-PTFE gaskets, plastic ball. Nylon interchangeable flanges with various connections and sizes available.
Maximum operating pressure 20bar – 290PSI with flowrate beyond 1000 lt/min on the 2” ½ model. 3 seconds closing time, 0,6 Amp
nominal absorption. Available in the ON/OFF and PROPORTIONAL versions with the opportunity of applying the angular sensor to detect
the position of the ball."
Cod. 00375701 Radial turbine plastic flowmeter for low flow rates (0.3 l/min to 9 l/min). BSP ¼" male threaded couplings with possibility of attachment to quick-couplings. Proximity sensor with LED to indicate operation. Made of plastic material resistant to corrosive liquid. Maximum operating pressure: 20 bar. The internal component coupling and the low proximity sensor magnetism allow the turbine to operate even at low flow rates while maintaining the reading accuracy at ±1%.
Cod. 00375702 Radial turbine plastic flowmeter for low flow rates (0.3 l/min to 9 l/min). BSP ¼" male threaded couplings with possibility of attachment to quick-couplings. Proximity sensor with LED to indicate operation. Made of plastic material resistant to corrosive liquid. Maximum operating pressure: 20 bar. The internal component coupling and the low proximity sensor magnetism allow the turbine to operate even at low flow rates while maintaining the reading accuracy at ±1%.
Cod. P0005142 TECHNICAL FEATURES · Filling and transferring of liquids. · Mixing of chemical products. · Internal washing of empty containers for chemical products. · Independent washing of the systems composing the unit. · Washing of the Sprayer. · Collection of the residues remaining in the Sprayer. TECHNICAL STRUCTURE · Polyethylene tanks with various capacities, fitted with cover equipped with quick funnel with rotating nozzles, wide angles flat nozzles for dissolving chemical products, vortex system for mixing and suction system for quick emptying.
Cod. 00185600 TECHNICAL FEATURES · Filling and transferring of liquids. · Mixing of chemical products. · Internal washing of empty containers for chemical products. · Independent washing of the systems composing the unit. · Washing of the Sprayer. · Collection of the residues remaining in the Sprayer. TECHNICAL STRUCTURE · Polyethylene tanks with various capacities, fitted with cover equipped with quick funnel with rotating nozzles, wide angles flat nozzles for dissolving chemical products, vortex system for mixing and suction system for quick emptying. · 500 liters/minute Centrifugal Pump. · 5,5 Kw Explosion Engine (Honda or Lombardini) to activate the Centrifugal Pump. · Cataphoresis treated steel frame, complete with wheels for movements. · Some models are equipped with an auxiliary tank to contain clean water, and with a 3·points connection for the coupling to the tractor lifter. · Tandem Ball Valve to control all the operative phases: A1 connected to suction. B1 connected to delivery.
Cod. 001859EL MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
Cod. 00185900 MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
Cod. 001858EL MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
Cod. 00185800 MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
Cod. 001857EL MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.