Cod. 00376208 REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges in the following sizes: 2" BSP - NPT and flanged hose tail Ø 50. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
Cod. 00376302 REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges in the following sizes: 2" BSP - NPT and flanged hose tail Ø 50. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
Cod. 00376204 REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges in the following sizes: 2" BSP - NPT and flanged hose tail Ø 50. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
Cod. 68110499 The electrohydraulic motor drive system applicable to all the 5-way (4 outlets) and 6-way (5 outlets) ball valves allows reaching any position using a hydraulic feed with a minimum pressure of 40 bar. The solenoid valve integrated in the system is connected to a 12VDC control which displays the ball position. There are three types of sensor to determine the position: microswitches, reed sensors and sensors for the radio frequency control.
Cod. 68110399 The electrohydraulic motor drive system applicable to all the 5-way (4 outlets) and 6-way (5 outlets) ball valves allows reaching any position using a hydraulic feed with a minimum pressure of 40 bar. The solenoid valve integrated in the system is connected to a 12VDC control which displays the ball position. There are three types of sensor to determine the position: microswitches, reed sensors and sensors for the radio frequency control.
Cod. 68110299 The electrohydraulic motor drive system applicable to all the 5-way (4 outlets) and 6-way (5 outlets) ball valves allows reaching any position using a hydraulic feed with a minimum pressure of 40 bar. The solenoid valve integrated in the system is connected to a 12VDC control which displays the ball position. There are three types of sensor to determine the position: microswitches, reed sensors and sensors for the radio frequency control.
Cod. P0005142 TECHNICAL FEATURES · Filling and transferring of liquids. · Mixing of chemical products. · Internal washing of empty containers for chemical products. · Independent washing of the systems composing the unit. · Washing of the Sprayer. · Collection of the residues remaining in the Sprayer. TECHNICAL STRUCTURE · Polyethylene tanks with various capacities, fitted with cover equipped with quick funnel with rotating nozzles, wide angles flat nozzles for dissolving chemical products, vortex system for mixing and suction system for quick emptying.
Cod. 00185600 TECHNICAL FEATURES · Filling and transferring of liquids. · Mixing of chemical products. · Internal washing of empty containers for chemical products. · Independent washing of the systems composing the unit. · Washing of the Sprayer. · Collection of the residues remaining in the Sprayer. TECHNICAL STRUCTURE · Polyethylene tanks with various capacities, fitted with cover equipped with quick funnel with rotating nozzles, wide angles flat nozzles for dissolving chemical products, vortex system for mixing and suction system for quick emptying. · 500 liters/minute Centrifugal Pump. · 5,5 Kw Explosion Engine (Honda or Lombardini) to activate the Centrifugal Pump. · Cataphoresis treated steel frame, complete with wheels for movements. · Some models are equipped with an auxiliary tank to contain clean water, and with a 3·points connection for the coupling to the tractor lifter. · Tandem Ball Valve to control all the operative phases: A1 connected to suction. B1 connected to delivery.
Cod. 001859EL MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
Cod. 00185900 MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
Cod. 001857EL MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
Cod. 00185700 MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
Cod. M0377045 "MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal
moving parts. Available in the versions with Delrin or polypropylene tunnel, 316 stainless
steel bushings. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter
consists of a centraI insulated part enclosed in a metal screen made of different types of
material, copper and stainless steel, to which the rigorously insulated electronic operating
components are connected. At the ends different attachments may be fitted to allow rapid
and compact coupling to other components of the sprayer control units. This inductive
magnetic flowmeter has a completely open tunnel without moving parts, indispensable for
measurement of certain liquids. The mixtures used in agricolture may have different characteristics
owing to the viscosity of the chemical and the temperature."
Cod. 00377045 "MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal
moving parts. Available in the versions with Delrin or polypropylene tunnel, 316 stainless
steel bushings. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter
consists of a centraI insulated part enclosed in a metal screen made of different types of
material, copper and stainless steel, to which the rigorously insulated electronic operating
components are connected. At the ends different attachments may be fitted to allow rapid
and compact coupling to other components of the sprayer control units. This inductive
magnetic flowmeter has a completely open tunnel without moving parts, indispensable for
measurement of certain liquids. The mixtures used in agricolture may have different characteristics
owing to the viscosity of the chemical and the temperature."
Cod. 00379014 TURBINE FLOWMETER WITH AUTOMATIC PROGRAMMABLE STOP Available in the sizes 1”½ (35-350 l/min) and 2” (75-750 l/min). Maximum pressure 3 bar. Allows programming the amount of liquid transfer; when reaching the set value, the passage manually opened with a lever automatically closes warning the operator with an acoustic signal. It comes in a Compact (1) and a Remote (2) version and can control other external devices (max. 5 A) such as a solenoid valve. The Parallel version can be fitted with a level sensor to be ordered separately.