Cod. 152250YV Use: hydraulically-driven forced air conveying system to be fitted on sprayers to generate an air flow that prevents dispersion of the products sprayed with the boom spraying nozzles. Fan unit composed of: · Sand-blasted and painted steel body · 700 Ø 14-blade fan with treated aluminium hub · Gearmotor or piston motor mounts · Protection grille · Provision for revolution counter · 8-hole flange coupling.
Cod. 152256Y9 Use: hydraulically-driven forced air conveying system to be fitted on sprayers to generate an air flow that prevents dispersion of the products sprayed with the boom spraying nozzles. Fan unit composed of: · Sand-blasted and painted steel body · 700 Ø 14-blade fan with treated aluminium hub · Gearmotor or piston motor mounts · Protection grille · Provision for revolution counter · 8-hole flange coupling.
Cod. 152250Y9 Use: hydraulically-driven forced air conveying system to be fitted on sprayers to generate an air flow that prevents dispersion of the products sprayed with the boom spraying nozzles. Fan unit composed of: · Sand-blasted and painted steel body · 700 Ø 14-blade fan with treated aluminium hub · Gearmotor or piston motor mounts · Protection grille · Provision for revolution counter · 8-hole flange coupling.
Cod. VTCD6000 The modular valve was born of the experience with the recirculation valve and the tandem valve and uses both technical concepts to control the entire distribution of the sprayer including the main on/off valve and the proportional pressure valve. Aluminium body treated with a cataphoresis cycle. Viton O-rings and Teflon-PTFE seals. Interchangeable Nylon flanges with different couplings and sizes. Possibility of constructing various models based on the sizes and the technical requirements to be satisfied.
Cod. 15216799 Hydraulic block with 12-24VDC powered electric actuator to regulate the hydraulic flow. Easy to fit on hydraulic circuits to activate the air sleeve fan and adjust its speed. Treated aluminium body and electric motor protected with an ABS cover.
Cod. 00375950 Extractable radial turbine flowmeter. Plastic flowmeter (IXEF) with stainless steel radial turbine. Rotation on graphite and ruby supports. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or Hall-effect sensors.
Cod. 00375951 Extractable radial turbine flowmeter. Plastic flowmeter (IXEF) with stainless steel radial turbine. Rotation on graphite and ruby supports. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or Hall-effect sensors.
Cod. 00376354 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. TT375154 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. RMF75154 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. RFM75154 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. BJ375154 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. 00376353 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. 00375853 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.