Search results for: 'WA 0812 2782 5310 Biaya Borong Pasang Interior Rumah Murah 10 Juta Murah Lendah Kulon Progo'
-
STANDARD FLOWMETER 60 BAR - STAINLESS STEEL BODY WITH THREADCod. NPT70125
STAINLESS STEEL (304-316) AXIAL-FLOW TURBINE FLOWMETER. Stainless steel body (304-316) in the versions with antacid plastic ducts (PVDF) or stainless steel ducts. This is the most suitable flowmeter for measuring corrosive and abrasive liquid chemical products at high working pressures. It can be used with a sinusoidal-wave or square-wave sensor, 4-20 mA.
DUCTSPVDFTHREAD1inch1/4 M. NPTMATERIALAISI 304SIZE1inchFLOW RATE10 - 100 Lt/MinSUPPORTSGRAPHITE
THREADED STAINLESS STEEL STANDARD FLOWMETER - 60 BAR SUITABLE FOR CONTACT WITH FOODSTUFFSCod. T0370355.ASTAINLESS STEEL AXIAL TURBINE FLOW METER.
AISI 316 stainless steel body, conveyors made of acid-resistant plastic material (PVDF), propeller with PTFE coating, ceramic supports, AISI 316 seeger rings.
Comestible liquids as follow are indicated in the measurement: water, oil, milk, wine, beer and vinegar; for this reason a declaration of conformity for contact with foodstuffs is provided, in accordance with the existing standards.
Resistant to high work pressures; can be combined with sine wave, square wave or Hall effect sensors.
DUCTSPVDFTHREAD2 INCH 1/2MATERIALAISI 316SIZE2 INCH 1/2FLOW RATE100 - 1000 Lt/MinSUPPORTSceramicNewNo
THREADED STAINLESS STEEL STANDARD FLOWMETER - 60 BAR SUITABLE FOR CONTACT WITH FOODSTUFFSCod. T0370325.ASTAINLESS STEEL AXIAL TURBINE FLOW METER.
AISI 316 stainless steel body, conveyors made of acid-resistant plastic material (PVDF), propeller with PTFE coating, ceramic supports, AISI 316 seeger rings.
Comestible liquids as follow are indicated in the measurement: water, oil, milk, wine, beer and vinegar; for this reason a declaration of conformity for contact with foodstuffs is provided, in accordance with the existing standards.
Resistant to high work pressures; can be combined with sine wave, square wave or Hall effect sensors.
DUCTSPVDFTHREAD1 INCH 1/4MATERIALAISI 316SIZE1 INCHFLOW RATE10 - 100 Lt/MinSUPPORTSceramicNewNoNew
INDUCTIVE FLOWMETERCod. M0377070
"MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Available in the versions with Delrin or polypropylene tunnel, 316 stainless steel bushings. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature."
MATERIALMOPLENSIZE3inchFLOW RATE100 - 2000 Lt/MinPRESSURE50 BARNewYesNew
INDUCTIVE FLOWMETERCod. 00377070
"MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Available in the versions with Delrin or polypropylene tunnel, 316 stainless steel bushings. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature."
MATERIALDELRINSIZE3inchFLOW RATE100 - 2000 Lt/MinPRESSURE50 BARNewYes
ECOTROLLCod. P0005142
TECHNICAL FEATURES · Filling and transferring of liquids. · Mixing of chemical products. · Internal washing of empty containers for chemical products. · Independent washing of the systems composing the unit. · Washing of the Sprayer. · Collection of the residues remaining in the Sprayer. TECHNICAL STRUCTURE · Polyethylene tanks with various capacities, fitted with cover equipped with quick funnel with rotating nozzles, wide angles flat nozzles for dissolving chemical products, vortex system for mixing and suction system for quick emptying.
SUPPLYNoCAPACITY42 LCOLORwhiteVERSION2R
ECOMOBCod. 00185600
TECHNICAL FEATURES · Filling and transferring of liquids. · Mixing of chemical products. · Internal washing of empty containers for chemical products. · Independent washing of the systems composing the unit. · Washing of the Sprayer. · Collection of the residues remaining in the Sprayer. TECHNICAL STRUCTURE · Polyethylene tanks with various capacities, fitted with cover equipped with quick funnel with rotating nozzles, wide angles flat nozzles for dissolving chemical products, vortex system for mixing and suction system for quick emptying. · 500 liters/minute Centrifugal Pump. · 5,5 Kw Explosion Engine (Honda or Lombardini) to activate the Centrifugal Pump. · Cataphoresis treated steel frame, complete with wheels for movements. · Some models are equipped with an auxiliary tank to contain clean water, and with a 3·points connection for the coupling to the tractor lifter. · Tandem Ball Valve to control all the operative phases: A1 connected to suction. B1 connected to delivery.
SUPPLYpetrolCAPACITY100 LCOLORwhiteVERSION2R
ECOBUS 600Cod. 001859EL
MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
SUPPLYELECTRICCAPACITY600 LCOLORwhiteVERSION4R
ECOBUS 600Cod. 00185900
MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
SUPPLYpetrolCAPACITY600 LCOLORwhiteVERSION4R
ECOBUS 300Cod. 001858EL
MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
SUPPLYELECTRICCAPACITY300 LCOLORwhiteVERSION4R
ECOBUS 300Cod. 00185800
MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
SUPPLYpetrolCAPACITY300 LCOLORwhiteVERSION4R
ECO3Cod. 001857EL
MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
SUPPLYELECTRICCAPACITY280 LCOLORwhiteVERSION3R
ECO3Cod. 00185700
MAIN OPERATIVE PHASES - The Tandem Ball Valve allows to have the operating levers on the same axis, thus making easier the series of operations to control the liquid through the different passages. 1) Filling of the Sprayer suctioning water from the outside (channel, well and so on). 2) During the Sprayer filling it is possible to introduce the mixed chemical products. 3) Mixing of the chemical products in a closed circuit/recycle. 4) Washing of containers for chemical products and washing of the structure. 5) Washing of the Sprayer and collection of the rinsing residues. 6) Quick transfer of the liquids.
SUPPLYpetrolCAPACITY280 LCOLORwhiteVERSION3R
TURBO FLOW - PLASTIC (IXEF) BODY WITH THREADED FLANGESCod. 00376503
MODULAR TURBINE FLOWMETER. This flowmeter’s interchangeable axial turbine makes it extremely versatile for measuring liquids with different levels of corrosiveness, viscosity and temperature. The practicality with which the turbines can be changed results in very simple maintenance, thus improving the precision and increasing the life of the instrument. Turbo Flow can be assembled with threaded connection flanges and different sizes of hose barbs, which can be replaced quickly and precisely. This allows components and connectors of different standards to be used.
MATERIALIXEFSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSR2
TURBO FLOW - PLASTIC (IXEF) BODY WITH THREADED FLANGESCod. 00376622
MODULAR TURBINE FLOWMETER. This flowmeter’s interchangeable axial turbine makes it extremely versatile for measuring liquids with different levels of corrosiveness, viscosity and temperature. The practicality with which the turbines can be changed results in very simple maintenance, thus improving the precision and increasing the life of the instrument. Turbo Flow can be assembled with threaded connection flanges and different sizes of hose barbs, which can be replaced quickly and precisely. This allows components and connectors of different standards to be used.
MATERIALIXEFSIZE2inch1/2FLOW RATE100 - 1000 Lt/MinPRESSURE25 BARSUPPORTSR1