Cod. P0005810-1 "3,5” digital color touchscreen display. Photo sensor to regulate back lighting. French, English, Italian and German multilingual menu. USB
port for data collection. Energy-saving with turning off after some minutes of inactivity. Choice of the number of decimals after comma.
ISOBUS Protocol. Rear coupling system with provision of suction cup attachment. It has two signals inputs for measuring the flow,
speed and filling level. 12Vcc power supply. Connected to a flowmeter the display indicates cumulative volume delivered (resettable)
up to 999.999 units and partial volume in different units of measure: litres, Usa gallons, mc/h. Setting of pulses for calibration of liquids
under several temperatures and viscosities. Setting of pulses for flowmeters from ½” to 4”. Can be connected to square wave sensors.
RAM-MOUNT suction cup compatible."
Cod. 00379014 TURBINE FLOWMETER WITH AUTOMATIC PROGRAMMABLE STOP Available in the sizes 1”½ (35-350 l/min) and 2” (75-750 l/min). Maximum pressure 3 bar. Allows programming the amount of liquid transfer; when reaching the set value, the passage manually opened with a lever automatically closes warning the operator with an acoustic signal. It comes in a Compact (1) and a Remote (2) version and can control other external devices (max. 5 A) such as a solenoid valve. The Parallel version can be fitted with a level sensor to be ordered separately.
Cod. 00379013 TURBINE FLOWMETER WITH AUTOMATIC PROGRAMMABLE STOP Available in the sizes 1”½ (35-350 l/min) and 2” (75-750 l/min). Maximum pressure 3 bar. Allows programming the amount of liquid transfer; when reaching the set value, the passage manually opened with a lever automatically closes warning the operator with an acoustic signal. It comes in a Compact (1) and a Remote (2) version and can control other external devices (max. 5 A) such as a solenoid valve. The Parallel version can be fitted with a level sensor to be ordered separately.
Cod. 003790G3 TURBINE FLOWMETER WITH AUTOMATIC PROGRAMMABLE STOP Available in the sizes 1”½ (35-350 l/min) and 2” (75-750 l/min). Maximum pressure 3 bar. Allows programming the amount of liquid transfer; when reaching the set value, the passage manually opened with a lever automatically closes warning the operator with an acoustic signal. It comes in a Compact (1) and a Remote (2) version and can control other external devices (max. 5 A) such as a solenoid valve. The Parallel version can be fitted with a level sensor to be ordered separately.
Cod. 003790G2 TURBINE FLOWMETER WITH AUTOMATIC PROGRAMMABLE STOP Available in the sizes 1”½ (35-350 l/min) and 2” (75-750 l/min). Maximum pressure 3 bar. Allows programming the amount of liquid transfer; when reaching the set value, the passage manually opened with a lever automatically closes warning the operator with an acoustic signal. It comes in a Compact (1) and a Remote (2) version and can control other external devices (max. 5 A) such as a solenoid valve. The Parallel version can be fitted with a level sensor to be ordered separately.
Cod. 00379010 TURBINE FLOWMETER WITH AUTOMATIC PROGRAMMABLE STOP Available in the sizes 1”½ (35-350 l/min) and 2” (75-750 l/min). Maximum pressure 3 bar. Allows programming the amount of liquid transfer; when reaching the set value, the passage manually opened with a lever automatically closes warning the operator with an acoustic signal. It comes in a Compact (1) and a Remote (2) version and can control other external devices (max. 5 A) such as a solenoid valve. The Parallel version can be fitted with a level sensor to be ordered separately.
Cod. 00379007 TURBINE FLOWMETER WITH AUTOMATIC PROGRAMMABLE STOP Available in the sizes 1”½ (35-350 l/min) and 2” (75-750 l/min). Maximum pressure 3 bar. Allows programming the amount of liquid transfer; when reaching the set value, the passage manually opened with a lever automatically closes warning the operator with an acoustic signal. It comes in a Compact (1) and a Remote (2) version and can control other external devices (max. 5 A) such as a solenoid valve. The Parallel version can be fitted with a level sensor to be ordered separately.
Cod. P0005810.V "Operating control for motorized ball valves.
Touch display, Isobus protocol. 12
volt or battery operating , radio connection.
Radiofrequency hall sensors position
card."
Cod. 01331799 Anti-overflow level sensor fitted on the tank, which allows automatic closure of the instrument when the liquid reaches the maximum level. When the tank is full, the flow is cut off even if the set value has not been reached. The system allows completely filling the tanks in full safety preventing the liquid from overflowing. It can be coupled to the Pro-Flow Parallel turbine versions.
Cod. RC379016 DISPLAY FOR FLOW MEASUREMENT AND READING The programmable multilingual graphic display can indicate: cumulative volume delivered (resettable), cumulative volume delivered (not resettable) and partial volume in different units of measure: litres/gallons per minute, cubic metres per hour. It can be applied to all our turbine flowmeters. Maximum reading error: ±1%. Backlit display. 9 Volts battery powered. Equipped with luminosity sensor to increase endurance and energy saving.
Cod. 0037901C DISPLAY FOR FLOW MEASUREMENT AND READING The programmable multilingual graphic display can indicate: cumulative volume delivered (resettable), cumulative volume delivered (not resettable) and partial volume in different units of measure: litres/gallons per minute, cubic metres per hour. It can be applied to all our turbine flowmeters. Maximum reading error: ±1%. Backlit display. 9 Volts battery powered. Equipped with luminosity sensor to increase endurance and energy saving.
Cod. 00379016 DISPLAY FOR FLOW MEASUREMENT AND READING The programmable multilingual graphic display can indicate: cumulative volume delivered (resettable), cumulative volume delivered (not resettable) and partial volume in different units of measure: litres/gallons per minute, cubic metres per hour. It can be applied to all our turbine flowmeters. Maximum reading error: ±1%. Backlit display. 9 Volts battery powered. Equipped with luminosity sensor to increase endurance and energy saving.
Cod. 83125200 The power supply must be chosen on the basis of the power absorbed by your application, taking into consideration that our displays have an absorption no greater than 0.5A uncharged.
Cod. 83125800 The power supply must be chosen on the basis of the power absorbed by your application, taking into consideration that our displays have an absorption no greater than 0.5A uncharged.
Cod. 83125600 The power supply must be chosen on the basis of the power absorbed by your application, taking into consideration that our displays have an absorption no greater than 0.5A uncharged.