Cod. P0005810-1 "3,5” digital color touchscreen display. Photo sensor to regulate back lighting. French, English, Italian and German multilingual menu. USB
port for data collection. Energy-saving with turning off after some minutes of inactivity. Choice of the number of decimals after comma.
ISOBUS Protocol. Rear coupling system with provision of suction cup attachment. It has two signals inputs for measuring the flow,
speed and filling level. 12Vcc power supply. Connected to a flowmeter the display indicates cumulative volume delivered (resettable)
up to 999.999 units and partial volume in different units of measure: litres, Usa gallons, mc/h. Setting of pulses for calibration of liquids
under several temperatures and viscosities. Setting of pulses for flowmeters from ½” to 4”. Can be connected to square wave sensors.
RAM-MOUNT suction cup compatible."
Cod. P0005810.4 "3,5” digital color touchscreen display. Photo sensor to regulate back lighting. French, English, Italian and German multilingual menu. USB
port for data collection. Energy-saving with turning off after some minutes of inactivity. Choice of the number of decimals after comma.
ISOBUS Protocol. Rear coupling system with provision of suction cup attachment. 12Vcc power supply. Connected to a flowmeter, the
display indicates real time lit/min flowrate and total flowrate. Setting of desired quantities also available to obtain an outlet signal once
the required value is reached. The outlet signal (2,6A) can produce luminous or audio pulses, can drive a 12Vcc gear motor or an electrovalve
or an engine. Also compatible with RAM-MOUNT suction cup."
Cod. P0005810.V "Operating control for motorized ball valves.
Touch display, Isobus protocol. 12
volt or battery operating , radio connection.
Radiofrequency hall sensors position
card."
Cod. P0005753 Pro-Flow with turbine flowmeter and programmable automatic stopping allows programming the desired amount of liquid transfer. Once the set amount is reached, the system automatically stops the flow. Supplied with a 2” threaded male coupling. 9V battery power supply included or with a 12VDC external power supply. Digital display, USB port to export the operating data, NO/NC contact output and input signal for connection to the filling level sensor. Flow rate up to 500 litres/minute (132 GPM) and maximum operating pressure of 12 bar (174 psi).
Cod. CH370000 INSTRUMENT FOR MEASURING AND READING REVOLUTIONS PER MINUTE. The 12 VDC powered, backlit Pony RPM in real-time measures the RPM of any rotary shaft fitted with a toothed measuring disk connected to the display. It is equipped with a device for remote control of an actuator or electric motor to increase or decrease the RPM. The operator can set the minimum and maximum value via the keypad together with the “0” value. Suitable for use with weeding booms with air sleeve.
Cod. 00379005 Liquid measuring and reading instrument with timed intermittent output signal. Liquid measuring and reading instrument with timed intermittent output signal. Connected to a flow meter it displays the real-time flow rate and the total flow rate. The desired quantity can be set to obtain an output signal (12 VDC 5A) controlled by a programmable timer. This function is activated at each multiple of the quantity set.
Cod. 00379015 Liquid measuring and reading instrument with timed intermittent output signal. Liquid measuring and reading instrument with timed intermittent output signal. Connected to a flow meter it displays the real-time flow rate and the total flow rate. The desired quantity can be set to obtain an output signal (12 VDC 5A) controlled by a programmable timer. This function is activated at each multiple of the quantity set.
Cod. RC379016 DISPLAY FOR FLOW MEASUREMENT AND READING The programmable multilingual graphic display can indicate: cumulative volume delivered (resettable), cumulative volume delivered (not resettable) and partial volume in different units of measure: litres/gallons per minute, cubic metres per hour. It can be applied to all our turbine flowmeters. Maximum reading error: ±1%. Backlit display. 9 Volts battery powered. Equipped with luminosity sensor to increase endurance and energy saving.
Cod. 0037901C DISPLAY FOR FLOW MEASUREMENT AND READING The programmable multilingual graphic display can indicate: cumulative volume delivered (resettable), cumulative volume delivered (not resettable) and partial volume in different units of measure: litres/gallons per minute, cubic metres per hour. It can be applied to all our turbine flowmeters. Maximum reading error: ±1%. Backlit display. 9 Volts battery powered. Equipped with luminosity sensor to increase endurance and energy saving.
Cod. 00379016 DISPLAY FOR FLOW MEASUREMENT AND READING The programmable multilingual graphic display can indicate: cumulative volume delivered (resettable), cumulative volume delivered (not resettable) and partial volume in different units of measure: litres/gallons per minute, cubic metres per hour. It can be applied to all our turbine flowmeters. Maximum reading error: ±1%. Backlit display. 9 Volts battery powered. Equipped with luminosity sensor to increase endurance and energy saving.
Cod. 83125200 The power supply must be chosen on the basis of the power absorbed by your application, taking into consideration that our displays have an absorption no greater than 0.5A uncharged.
Cod. 83125800 The power supply must be chosen on the basis of the power absorbed by your application, taking into consideration that our displays have an absorption no greater than 0.5A uncharged.
Cod. 83125600 The power supply must be chosen on the basis of the power absorbed by your application, taking into consideration that our displays have an absorption no greater than 0.5A uncharged.
Cod. 83125400 The power supply must be chosen on the basis of the power absorbed by your application, taking into consideration that our displays have an absorption no greater than 0.5A uncharged.
Cod. 83125500 The power supply must be chosen on the basis of the power absorbed by your application, taking into consideration that our displays have an absorption no greater than 0.5A uncharged.