Cod. BJ375101 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. RFM75152 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. RMF75151 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. BJ375153 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. 00375154 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. 00375153 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. 00375152 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. 00375151 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. 00375101 REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
Cod. 44314799 EXTRACTABLE FLOWMETER easy to apply and connect to any pipe of different diameter for perfect flow measurement. The compact size allows only partially occupying the duct leaving the inner span of the pipe almost completely free. Sin-wave, square-wave and 4-20 mA sensors. Battery-operated or 12V electrically-operated displays to view units per minute and totals, expressed in litres, hectolitres, cubic metres or gallons. Error percentage: ±3%. Response time: 3 sec.
Cod. 44312899 EXTRACTABLE FLOWMETER easy to apply and connect to any pipe of different diameter for perfect flow measurement. The compact size allows only partially occupying the duct leaving the inner span of the pipe almost completely free. Sin-wave, square-wave and 4-20 mA sensors. Battery-operated or 12V electrically-operated displays to view units per minute and totals, expressed in litres, hectolitres, cubic metres or gallons. Error percentage: ±3%. Response time: 3 sec.
Cod. 44302799 EXTRACTABLE FLOWMETER easy to apply and connect to any pipe of different diameter for perfect flow measurement. The compact size allows only partially occupying the duct leaving the inner span of the pipe almost completely free. Sin-wave, square-wave and 4-20 mA sensors. Battery-operated or 12V electrically-operated displays to view units per minute and totals, expressed in litres, hectolitres, cubic metres or gallons. Error percentage: ±3%. Response time: 3 sec.
Cod. 44312799 EXTRACTABLE FLOWMETER easy to apply and connect to any pipe of different diameter for perfect flow measurement. The compact size allows only partially occupying the duct leaving the inner span of the pipe almost completely free. Sin-wave, square-wave and 4-20 mA sensors. Battery-operated or 12V electrically-operated displays to view units per minute and totals, expressed in litres, hectolitres, cubic metres or gallons. Error percentage: ±3%. Response time: 3 sec.
Cod. 00375701 Radial turbine plastic flowmeter for low flow rates (0.3 l/min to 9 l/min). BSP ¼" male threaded couplings with possibility of attachment to quick-couplings. Proximity sensor with LED to indicate operation. Made of plastic material resistant to corrosive liquid. Maximum operating pressure: 20 bar. The internal component coupling and the low proximity sensor magnetism allow the turbine to operate even at low flow rates while maintaining the reading accuracy at ±1%.
Cod. 00375702 Radial turbine plastic flowmeter for low flow rates (0.3 l/min to 9 l/min). BSP ¼" male threaded couplings with possibility of attachment to quick-couplings. Proximity sensor with LED to indicate operation. Made of plastic material resistant to corrosive liquid. Maximum operating pressure: 20 bar. The internal component coupling and the low proximity sensor magnetism allow the turbine to operate even at low flow rates while maintaining the reading accuracy at ±1%.