Cod. M0377045 "MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal
moving parts. Available in the versions with Delrin or polypropylene tunnel, 316 stainless
steel bushings. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter
consists of a centraI insulated part enclosed in a metal screen made of different types of
material, copper and stainless steel, to which the rigorously insulated electronic operating
components are connected. At the ends different attachments may be fitted to allow rapid
and compact coupling to other components of the sprayer control units. This inductive
magnetic flowmeter has a completely open tunnel without moving parts, indispensable for
measurement of certain liquids. The mixtures used in agricolture may have different characteristics
owing to the viscosity of the chemical and the temperature."
Cod. 00377045 "MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal
moving parts. Available in the versions with Delrin or polypropylene tunnel, 316 stainless
steel bushings. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter
consists of a centraI insulated part enclosed in a metal screen made of different types of
material, copper and stainless steel, to which the rigorously insulated electronic operating
components are connected. At the ends different attachments may be fitted to allow rapid
and compact coupling to other components of the sprayer control units. This inductive
magnetic flowmeter has a completely open tunnel without moving parts, indispensable for
measurement of certain liquids. The mixtures used in agricolture may have different characteristics
owing to the viscosity of the chemical and the temperature."
Cod. 00200530.1 IXEF body, Viton OR and PTFE-Teflon gaskets, AISI 316 stainless steel ball. Nylon interchangeable flanges with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate up to 600 lt/min. 8 seconds closing time, 0,2 Amp nominal absorption. The special setting of the section hole of the valve guarantees an exact and accurate control of flow. If applied along the lineat suction of a centrifugal pump, it allows a better steadiness of flow.
Cod. 00200500 "IXEF body, Viton OR and Teflon-PTFE gaskets, AISI 316 stainless steel ball with continuous flow system. Nylon interchangeable flanges
with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate up to 500 lt/min. 1,3 seconds
closing time, 0,3 nominal absorption. Also available with lateral or lower inlet."
Cod. 00200501 "IXEF body, Viton OR and Teflon-PTFE gaskets, AISI 316 stainless steel ball with continuous flow system. Nylon interchangeable flanges
with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate up to 500 lt/min. 1,3 seconds
closing time, 0,3 nominal absorption. Also available with lateral or lower inlet."
Cod. 00200701.ME "Plastic body, Viton OR and Teflon-PTFE gaskets, plastic ball. Nylon interchangeable flanges with various connections and sizes available.
Maximum operating pressure 20bar – 290PSI with flowrate beyond 1000 lt/min on the 2” ½ model. 3 seconds closing time, 0,6 Amp
nominal absorption. Available in the ON/OFF and PROPORTIONAL versions with the opportunity of applying the angular sensor to detect
the position of the ball."
Cod. 00200701 "Plastic body, Viton OR and Teflon-PTFE gaskets, plastic ball. Nylon interchangeable flanges with various connections and sizes available.
Maximum operating pressure 20bar – 290PSI with flowrate beyond 1000 lt/min on the 2” ½ model. 3 seconds closing time, 0,6 Amp
nominal absorption. Available in the ON/OFF and PROPORTIONAL versions with the opportunity of applying the angular sensor to detect
the position of the ball."
Cod. VTD93510 "IXEF body. Viton OR. Teflon-PTFE gaskets. Delrin ball and nylon flanges with various connectors and different sizes. The specific shape
of the ball and the internal Venturi, enable the valve to carry out suction and delivery functions at the same time. The system allows to
always have a way in depression to use for suctioning liquids. In combination with a two ways valve, “dead man” model, carries out many
functions under the maximum safety conditions."
Cod. P0005810.4 "3,5” digital color touchscreen display. Photo sensor to regulate back lighting. French, English, Italian and German multilingual menu. USB
port for data collection. Energy-saving with turning off after some minutes of inactivity. Choice of the number of decimals after comma.
ISOBUS Protocol. Rear coupling system with provision of suction cup attachment. 12Vcc power supply. Connected to a flowmeter, the
display indicates real time lit/min flowrate and total flowrate. Setting of desired quantities also available to obtain an outlet signal once
the required value is reached. The outlet signal (2,6A) can produce luminous or audio pulses, can drive a 12Vcc gear motor or an electrovalve
or an engine. Also compatible with RAM-MOUNT suction cup."
Cod. P0005810-1 "3,5” digital color touchscreen display. Photo sensor to regulate back lighting. French, English, Italian and German multilingual menu. USB
port for data collection. Energy-saving with turning off after some minutes of inactivity. Choice of the number of decimals after comma.
ISOBUS Protocol. Rear coupling system with provision of suction cup attachment. It has two signals inputs for measuring the flow,
speed and filling level. 12Vcc power supply. Connected to a flowmeter the display indicates cumulative volume delivered (resettable)
up to 999.999 units and partial volume in different units of measure: litres, Usa gallons, mc/h. Setting of pulses for calibration of liquids
under several temperatures and viscosities. Setting of pulses for flowmeters from ½” to 4”. Can be connected to square wave sensors.
RAM-MOUNT suction cup compatible."
Cod. P0005810.V "Operating control for motorized ball valves.
Touch display, Isobus protocol. 12
volt or battery operating , radio connection.
Radiofrequency hall sensors position
card."
Cod. 44305599 "Connectable to all axial turbine Rapid Check flowmeters. It allows simple and rapid disassembly so that the moving parts can be inspected.
High and low volume versions can be mounted on the same flowmeter body so that it can be used for both applications."
Cod. P1002095 "Component with double function to dissolve chemicals and rinse their containers. Easy to apply, it can be fitted inside the bag filters of
atomizers and allows a quick dissolving of chemicals and an effective rinsing of container. Equipped with film cutting nozzle and spring
return valve, it allows the operator to carry out manoeuvres in absolute safety. Made of anticorrosive material."
Cod. M0377070 "MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal
moving parts. Available in the versions with Delrin or polypropylene tunnel, 316 stainless
steel bushings. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter
consists of a centraI insulated part enclosed in a metal screen made of different types of
material, copper and stainless steel, to which the rigorously insulated electronic operating
components are connected. At the ends different attachments may be fitted to allow rapid
and compact coupling to other components of the sprayer control units. This inductive
magnetic flowmeter has a completely open tunnel without moving parts, indispensable for
measurement of certain liquids. The mixtures used in agricolture may have different characteristics
owing to the viscosity of the chemical and the temperature."