FLOWMETERS

-
RAPID CHECK 50 BAR - IXEF BODY WITH THREADED FLANGESCod. 00375902
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE1inchFLOW RATE3 - 20 Lt/MinPRESSURE50 BARSUPPORTSR1NewNo
RAPID CHECK 50 BAR - IXEF BODY WITH THREADED FLANGESCod. 00375804
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSceramicNewNo
RAPID CHECK 50 BAR - IXEF BODY WITH THREADED FLANGESCod. 00375802
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE1inchFLOW RATE3 - 20 Lt/MinPRESSURE50 BARSUPPORTSceramicNewNo
RAPID CHECK 50 BAR - IXEF BODY WITH THREADED FLANGESCod. 00375803
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSNoNewNo
RAPID CHECK 50 BAR - IXEF BODY WITH THREADED FLANGESCod. 00375801
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE1inchFLOW RATE3 - 20 Lt/MinPRESSURE50 BARSUPPORTSNoNewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PMSM7053
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALPPSIZE1inchFLOW RATE10 - 200 Lt/MinPRESSURE50 BARNewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PMM77053
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALPPSIZE1inchFLOW RATE10 - 200 Lt/MinPRESSURE50 BARNewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. M0377053
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
APPLICATIONNoMATERIALPPSIZE1inchFLOW RATE10 - 200 Lt/MinPRESSURE50 BARNewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PMS77053
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALDELRINSIZE1inchFLOW RATE10 - 200 Lt/MinPRESSURE50 BARNewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PM377053
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
APPLICATIONNoMATERIALDELRINSIZE1inchFLOW RATE10 - 200 Lt/MinPRESSURE50 BARNewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. 00377053
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
APPLICATIONNoMATERIALDELRINSIZE1inchFLOW RATE10 - 200 Lt/MinPRESSURE50 BARNewNo
RAPID CHECK UNIT RADIAL VERSIONCod. 41370199
Extractable radial turbine flowmeter.
Plastic flowmeter (IXEF) with stainless steel radial turbine. Rotation on graphite and ruby supports. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or Hall-effect sensors.
SIZE1inchFLOW RATE10 - 100 Lt/MinSUPPORTSGRAPHITENewNo
RAPID CHECK UNIT RADIAL VERSIONCod. 41370299
Extractable radial turbine flowmeter.
Plastic flowmeter (IXEF) with stainless steel radial turbine. Rotation on graphite and ruby supports. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or Hall-effect sensors.
SIZE1inchFLOW RATE10 - 100 Lt/MinSUPPORTSR2NewNo
RAPID CHECK UNIT RADIAL VERSIONCod. 41370799
Extractable radial turbine flowmeter.
Plastic flowmeter (IXEF) with stainless steel radial turbine. Rotation on graphite and ruby supports. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or Hall-effect sensors.
SIZE1inchFLOW RATE10 - 100 Lt/MinSUPPORTSZRNewNo
RAPID CHECK UNIT - IXEF BODYCod. 41301899
Connectable to all axial turbine Rapid Check flowmeters.
It allows simple and rapid disassembly so that the moving parts can be inspected. High and low volume versions can be mounted on the same flowmeter body so that it can be used for both applications.
SIZE1inchFLOW RATE3 - 20 Lt/MinSUPPORTSCUSCINETTINewNo








