FLOWMETERS

-
RAPID CHECK RADIAL VERSIONCod. 00375950
Extractable radial turbine flowmeter.
Plastic flowmeter (IXEF) with stainless steel radial turbine. Rotation on graphite and ruby supports. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or Hall-effect sensors.
MATERIALIXEFSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSGRAPHITENewNo
RAPID CHECK 50 BAR - IXEF BODY WITH THREADED FLANGESCod. 00375911
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSGRAPHITENewNo
RAPID CHECK 50 BAR - IXEF BODY WITH THREADED FLANGESCod. 00375903
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSR2NewNo
RAPID CHECK 50 BAR - IXEF BODY WITH THREADED FLANGESCod. 00375908
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSZRNewNo
RAPID CHECK 50 BAR - IXEF BODY WITH THREADED FLANGESCod. 00375904
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSR1NewNo
RAPID CHECK 50 BAR - IXEF BODY WITH THREADED FLANGESCod. 00375804
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSceramicNewNo
RAPID CHECK 50 BAR - IXEF BODY WITH THREADED FLANGESCod. 00375803
REMOVABLE TURBINE FLOWMETER. Plastic (IXEF) flowmeter with a stainless steel axial turbine. Rotation takes pIace on these supports: stainless steel (bearings), ceramic or ruby. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or 4-20 mA sensors.
MATERIALIXEFSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSNoNewNo
RAPID CHECK RADIAL VERSIONCod. 00375951
Extractable radial turbine flowmeter.
Plastic flowmeter (IXEF) with stainless steel radial turbine. Rotation on graphite and ruby supports. Flowmeter body with removable male threaded flanges and flanged hosetail. Removable turbine unit and sensor. Sinusoidal-wave, square-wave or Hall-effect sensors.
MATERIALIXEFSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSR2NewNo
RAPID CHECK PLUS WITH FLANGESCod. BJ375103
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
THREADBJ 52 mmMATERIALNYLONSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSZAFFIRO REGISTRABILENewNo
RAPID CHECK PLUS WITH FLANGESCod. TJ375103
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
THREADTEEJETMATERIALNYLONSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSZAFFIRO REGISTRABILENewNo
RAPID CHECK PLUS WITH FLANGESCod. TJ375101
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
THREADTEEJETMATERIALNYLONSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSZAFFIRO/ CARBURO - TUNGSTENONewNo
RAPID CHECK PLUS WITH FLANGESCod. 375101
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
THREAD1 1/4" MMATERIALIXEFSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSZAFFIRO/ CARBURO - TUNGSTENONewNo
RAPID CHECK PLUS WITH FLANGESCod. BJ375101
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
THREADBJ 52 mmMATERIALNYLONSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSZAFFIRO/ CARBURO - TUNGSTENONewNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. TJ375232
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSGRAPHITENewNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. TJ375234
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSR2NewNo