RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RMF75253
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSR1VERSIONNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM75253
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSR1VERSIONNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RMF75255
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSZRVERSIONNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM75255
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSZRVERSIONNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RMF75252
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSceramicVERSIONNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM75252
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSceramicVERSIONNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RMF75251
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSNoVERSIONNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM75251
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZENoFLOW RATE17 - 170 Lt/MinPRESSURE20 BARSUPPORTSNoVERSIONNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM78001
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE1/2inchFLOW RATE3 - 20 Lt/MinPRESSURE20 BARSUPPORTSceramicVERSIONNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM78051
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE3/4inchFLOW RATE7 - 70 Lt/MinPRESSURE20 BARSUPPORTSceramicVERSIONNo
RAPID CHECK PLUS WITH FLANGESCod. TJ375103
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
MATERIALNYLONSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSZR
RAPID CHECK PLUS WITH FLANGESCod. TJ375101
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
MATERIALNYLONSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSZT
RAPID CHECK PLUS WITH FLANGESCod. BJ375102
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
MATERIALNYLONSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSZC
RAPID CHECK PLUS WITH FLANGESCod. BJ375101
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
MATERIALNYLONSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSZT
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. TJ375232
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSGRAPHITE