Search results for: 'WA'
-
VALVOLA MANUALE 1 ¼” A 2 VIECod. P2000100.SVALVOLA MANUALE 1 ½” a 2 VIE, SFERA D. 78, foro 44,5 mm, con staffe acciaio inox AISI 303.
NewNo
VALVOLA MANUALE 1 ¼” A 2 VIECod. P2000100VALVOLA MANUALE 1 ½” a 2 VIE, SFERA D. 78, foro 44,5 mm, senza staffe
NewNo
VALVOLA MANUALE 1 ¼” A 2 VIECod. P2000600VALVOLA MANUALE 1 ¼” A 2 VIE, SFERA D. 50 FORO 32 mm, sfera in acetalica, guarnizione in delrin
NewNo
R100 BOOM HIGH FLOWRATE SECTION VALVE WITH 12VCC ELECTRIC OPERATION.Cod. P1002941.7
"IXEF body, Viton OR and Teflon-PTFE gaskets, Aisi 316 stainless steel ball. Nylon interchangeable flanges with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate beyond 150 lt/min. 1,3 seconds closing time, 0,3 Amp nominal absorption."
SUPPLY12VMATERIALNYLONFLOW RATE30 Lt/MinPRESSURE20 BARNewNo
R100 BOOM HIGH FLOWRATE SECTION VALVE WITH 12VCC ELECTRIC OPERATION.Cod. P10002190.3
"IXEF body, Viton OR and Teflon-PTFE gaskets, Aisi 316 stainless steel ball. Nylon interchangeable flanges with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate beyond 150 lt/min. 1,3 seconds closing time, 0,3 Amp nominal absorption."
SUPPLY12VMATERIALNYLONFLOW RATE200 Lt/MinPRESSURE20 BARNewNo
R100 BOOM HIGH FLOWRATE SECTION VALVE WITH 12VCC ELECTRIC OPERATION.Cod. 00200551.9
"IXEF body, Viton OR and Teflon-PTFE gaskets, Aisi 316 stainless steel ball. Nylon interchangeable flanges with various connections and sizes available. Maximum operating pressure 20bar – 290PSI with flowrate beyond 150 lt/min. 1,3 seconds closing time, 0,3 Amp nominal absorption."
SUPPLY12VMATERIALNYLONFLOW RATE150 Lt/MinPRESSURE20 BARNewNo
DISPLAY REMOTO PER CONTALITRI MAGNETICOCod. 00379009.SCapace di misurare i litri al minuto ed i litri complessivamente erogati
Si può impostare una quantità erogata, al raggiungimento della quale
Possiamo avere un segnale in uscita a 12 volt.
Questo segnale può esser trasformato in un cicalino sonoro o visivo per l'operatore oppure può chiudere una Elettrovalvola o una valvola motorizzata.
NewNo
DISPLAY REMOTO PER CONTALITRI MAGNETICOCod. 00379009CAPACE DI MISURARE I LITRI AL MINUTO ED I LITRI COMPLESSIVAMENTE EROGATI
NewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PMSM7070
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALMOPLENSIZE3"FLOW RATE1 - 30 Lt/MinPRESSURE10 BARNewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PMS77070
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALDELRINSIZE3"FLOW RATE1 - 30 Lt/MinPRESSURE10 BARNewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PMSM7051
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALMOPLENSIZE1/2"FLOW RATE1 - 30 Lt/MinPRESSURE50 BARNewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PMSM7045
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALMOPLENSIZE1/4"FLOW RATE0.3 - 6 Lt/MinPRESSURE50 BARNewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PMS77045
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALDELRINSIZE1/4"FLOW RATE0.3 - 6 Lt/MinPRESSURE50 BARNewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PMM77070
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALMOPLENSIZE3"FLOW RATE100 - 2000 Lt/MinPRESSURE10 BARNewNo
MAGNETIC FLOW - INDUCTIVE FLOWMETERCod. PM377070
MAGNETIC INDUCTION FLOWMETER 12 volts powered, square wave sensor without internal moving parts. Delrin tunnel, stainless steel 316 bushes. Suitable for all water-based liquid chimicals. The inductive magnetic flowmeter consists of a centraI insulated part enclosed in a metal screen made of different types of material, copper and stainless steel, to which the rigorously insulated electronic operating components are connected. At the ends different attachments may be fitted to allow rapid and compact coupling to other components of the sprayer control units. This inductive magnetic flowmeter has a completely open tunnel without moving parts, indispensable for measurement of certain liquids. The mixtures used in agricolture may have different characteristics owing to the viscosity of the chemical and the temperature.
MATERIALDELRINSIZE3"FLOW RATE100 - 2000 Lt/MinPRESSURE10 BARNewNo