FLOWMETERS

-
RAPID CHECK PLUS WITH FLANGESCod. RFM75153
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
THREADT7 F-MMATERIALNYLONSIZE1"1/2FLOW RATE35 - 350 Lt/MinPRESSURE20 BARSUPPORTSZAFFIRO REGISTRABILENewNo
RAPID CHECK PLUS WITH FLANGESCod. TJ375103
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
THREADTEEJETMATERIALNYLONSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSZAFFIRO REGISTRABILENewNo
RAPID CHECK PLUS WITH FLANGESCod. TJ375101
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
THREADTEEJETMATERIALNYLONSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSZAFFIRO/ CARBURO - TUNGSTENONewNo
RAPID CHECK PLUS WITH FLANGESCod. 375101
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
THREAD1 1/4" MMATERIALIXEFSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE50 BARSUPPORTSZAFFIRO/ CARBURO - TUNGSTENONewNo
RAPID CHECK PLUS WITH FLANGESCod. BJ375101
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
THREADBJ 52 mmMATERIALNYLONSIZE1"FLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSZAFFIRO/ CARBURO - TUNGSTENONewNo
RAPID CHECK PLUS WITH FLANGESCod. BJ375153
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
THREADBJ 77 mmMATERIALNYLONSIZE1"1/2FLOW RATE35 - 350 Lt/MinPRESSURE20 BARSUPPORTSZAFFIRO REGISTRABILENewNo
RAPID CHECK PLUS WITH THREADCod. 00375154
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
MATERIALNYLONSIZE1"1/2FLOW RATE35 - 350 Lt/MinPRESSURE20 BARSUPPORTSceramicNewNo
RAPID CHECK PLUS WITH THREADCod. 00375153
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
MATERIALNYLONSIZE1"1/2FLOW RATE35 - 350 Lt/MinPRESSURE20 BARSUPPORTSZRNewNo
RAPID CHECK PLUS WITH THREADCod. .00375101
REMOVABLE TURBINE FLOWMETER. The Rapid Check Plus flowmeters complete the Rapid Check series offering enhanced conveyance of the liquid to be measured and high maintenance practicality. The cantilever turbine turns on sapphire supports with steel or ceramic shaft. Available in the versions with a maximum pressure of 20 bar (1” – 1½”), 40 bar (1½”) and 50 bar (1”) with interchangeable flanges. The axial turbine and the sinusoidal-wave, square-wave or Hall-effect sensor are installed on one single removable element.
MATERIALNYLONSIZE1inchFLOW RATE10 - 100 Lt/MinPRESSURE20 BARSUPPORTSZTNewNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RMF76012
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSZRVERSIONNoNewNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RMF76106
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSR1VERSIONNoNewNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM76106
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSR1VERSIONNoNewNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM76012
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSZRVERSIONNoNewNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RMF76008
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSceramicVERSIONNoNewNo
RAPID CHECK 20 BAR - NYLON BODY WITH FLANGESCod. RFM76008
REMOVABLE TURBINE FLOWMETER. The Rapid Check flowmeter series is extremely practical when carrying out maintenance operations, and maintains the precision of the standard turbine flowmeters. It is possible to simply unscrew the body to remove, check, and (if necessary) clean the stainless steel axial-flow turbine. A single removable body contains a turbine (with stainless steel, ceramic, ruby or adjustable sapphire bearings) and a sinusoidal-wave or square-wave sensor, 4-20mA.
MATERIALNYLONSIZE2inchFLOW RATE75 - 750 Lt/MinPRESSURE20 BARSUPPORTSceramicVERSIONNoNewNo